More for renovations,
or in industrial premises.
Cassa France Oyonnax
Rising
concrete wall
BA13 installed screwed
Rail
Rising
Rising
BA13
Height of the ba13 3 m, to receive the ceiling at 2.80 m
Example of fixing for the top of the doubling.
The maximum height of the counter partitions made with
furs (F 530) is limited to 10 m between floor and ceiling with the
uprights M 36 to M 90, the height is not limited.
In addition to this, you need to know more about it.
BENEFITS
Integration of pipelines.
High performance.
Elimination of the risk of
cracking.
Half-style
The plasterboard lining, which is also called half-style, against the partition. It is mainly used for rehabilitation, complete separation from the
wall to be lined, improved thermal and acoustic insulation of the walls, cladding and straightening of existing walls. This dubbing is good
to pass the sheaths, the brass, the flows, finally whatever you want, since it is you who choose the thickness of the dubbing. The
vertical uprights are single or double depending on the height of the wall. As for a partition, put a rail on the ground (R48) a rail in
top, the uprights every 60cm over the entire height, put a square at each upright in the middle of 2.50 then fix against the uprights one, 2 or 3 BA13. The more plasterboard there is, the better the acoustic performance.
From two plates, it is recalled that the vertical joints of the plates must be offset.
Ceiling
1 BA13
2 BA13
15cm
great height
In partition as in doubling
Floor
48 rail
Amount of 48
Drop rail or upright bracket
Secure the 48 mm rails by pegging, screwing ... every 0.70 m maximum.
Take the ceiling height and cut the uprights of 48
mm to dimension, minus 5mm
Secure the supports to the wall by gluing (Map) or drilling with a 6-gauge plug.
After installation of the glass wool panels or
rock, thickness 45, 65, 75, 100, 200 mm screwing of
plates on the frames.
trick
Mark the position of the uprights on the floor and on the ceiling. These
marks will be useful when screwing
plates
Maximum distance between supports with plates at
thinned edges and joints with tape.
On fur, a BA 13 1.25m
"" two BA 13 1.50m
On upright, a BA 13 2.10m
"" two BA 13 2.50m
please wait for a few moments
Another frame diagram
wall head
Glue (map)
Rail
Rising
Plasterboard BA13, BA15...
masonry wall
More than 0.60 m in height
Less than 0.60 m in height
0.60m
On double uprights
Tableau gestion des heures de travail
Tableau simple annualisation des heures.
Calcule automatiquement les heures de travail effectuées, qu'elles soient journalières, mensuelles ou annuelles.
Tableau de calc de temps à télécharger, au jour, à la semaine ou au mois.
Deep framework
Semi-rigid panel of glass wool coated with steam kraft th. 75 - 100 - 120 mm ...
Rising
Rising
Pipe
Four examples of cutting in the plasterboard, for the pipe outlet.
please wait for a few moments
High-rise upright frame lining
High acoustic performance
Counter-partition formed by assembling one or two plates screwed onto
the same face of a vertical frame (upright).
The construction gap between the vertical wall to be lined and the
cladding against the partition allows the incorporation of an insulating blanket.
1: Plate
2: Tape joint treatment and
coated
3: Rail
4: Amount
5: Screw
6: Insulation (2 crossed layers)
7: Air seal
Very high acoustic counter-partition made up of
assembly of 2 or 3 plates screwed onto the same side of a frame
vertical (in uprights) linked to the support by PHONI spacers
SL with incorporation of an insulating mat.
1: Plate
2: Tape joint treatment and
coated
3: Rail
4: Contiguous amounts
5: PHONI SL link
6: Air seal