Independent ceiling
If you want to make a BA13 ceiling between partitions, nothing could be easier!
ADVANTAGES For new or old construction sites.
Low load or not at all under floors, roofs.
Integration of pipelines.
High performance.
Elimination of the risk of cracking.
Rail
Forget the F530s. To make a self-supporting false ceiling, you have to put a rail (r48) on each side of the wall horizontally and at the desired height. Example 2.50 + BA13 = 2.513. Fix the rail
using screws (on plasterboard), dowels diameter 6 or 5, length 25 mm (on concrete or brick tiles). The M48 uprights interlock on either side of the end. Fix them every 60 cm maximum.
Beyond an edge span of 1.80 m,
the angle is replaced by a rail.
In the case of self-supporting ceilings, furring strips are not permitted.
Amount
Rail
Parker screw
If the walls are separated more
2.10 m for a frame in
48mm, put a square on
each amount.
(See diagram)
Rising
Drop rail or upright bracket
please wait for a few moments
masonry wall
Rising
Plasterboard
LEDs
Slab
please wait for a few moments
The ceiling on uprights allows greater spans between hangers than with F 530 profiles.
Maximum range without lines, (square).
M48 upright 2.10m. M48 lined back to back 2.50m.
Upright M70 2.70m. M70 lined back to back 3.20m.
Upright M90 3.15m. M90 lined back to back 3.70m
The ceiling is supported by partitions or walls.
For corridors or passageways and small rooms (width
less than 3.70m, without hanger), solutions on uprights (M48, M70 and M90)
allow you to cross spans without an intermediate line. Possibility of
make inspection hatches.
Glass wool placed directly on the uprights
Rail
Amounts
Plasterboard
Ceiling between the beams. A rail (r 48) must be placed on each side of the beams horizontally and at the desired height.
Secure the rail to the beam using 25 mm plasterboard screws, fix BA 13.
The joint between the beam and the acrylic plasterboard.
Rail R48 Upright
BA seal 13 screws of 25 mm
Acrylic and non-silicone sealant!
For what reason and not acrylic silicone
ACRYLIC SEALANT Joint joints inside and outside. Can be painted, and not silicone (name given to silicon derivatives which are in the form of oils). Door and door connections
windows, filling of cracks in cellular concrete. Complete thermal insulation. Instructions for use: the adhesion surfaces of the joint must be load-bearing, dry, clean, free from all
traces of grease and dust. Max joint width : 20mm for the use of the primer (first coat). Smoothing: with a finger and soaped water! Cannot be painted until a hard film has formed.
Other: bias frame
Rising
Wall
Rail
Fixing in the wall.
Screw or dowel.